Gas Burner TBG ME Series
Technical data
- Electronic two-stage progressive / Modulating gas burners
- Available model : TBG35 ME, TBG45 ME, TBG60 ME, TBG85 ME, TBG120 ME, TBG150 ME, TBG210 ME, TBG260 ME, TBG360 ME, TBG480 ME, TBG600 ME, TBG800 ME, TBG900 ME, TBG1100 ME, TBG1200 ME, TBG1600 ME, TBG2000 ME
- Maximun output range (kW) : 410 – 22000
- Power Supply Voltage (V) : 220 (TBG35 ME, TBG45 ME) / 380
- Power Supply Frequency (Hz): 50
Technical Descriptions (TBG35 ME, TBG45 ME, TBG60 ME, TBG85 ME, TBG120 ME, TBG150 ME, TBG210 ME, TBG260 ME, TBG360 ME)
-
Gas burner compliant with European standard EN676. Electronic operation at two progressive / modulating stages
-
Continuous modulation operation by installing P.I.D. controller in the control panel (to be ordered separately with modulation probe)
-
Modulation ratio 1:5 / 1:4 (TBG45 MC ONLY)
-
Gas burner with low NOx and CO emissions in accordance with European standard EN676: class 3
-
Regulating combustion air and blast-pipe
-
Combustion air intake with throttle damper. Air flow adjustment with electric servomotor
-
Fully closing air damper on shutdown to avoid loss of heat through the chimney
-
Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler
-
Sliding boiler coupling flange to adapt the blast-pipe to the various types of boilers
-
CE version gas train is complete with butterfly valve, operation and safety valve with electromagnetic drive, minimum pressure switch, pressure regulator and gas filter
-
Possibility to choose gas train with valve tightness control
-
Fail proof connectors for burner/gas train connection
-
Gas train exit: down
-
Flame detection by ionisation electrode with connector for micro amp meter
-
7-pole socket for burner electric and thermostatic supply
-
4-pole socket for second stage control or for the connection of the PID electronic regulator
-
Electric protection rating: IP40
-
Gas burner compliant with European standard EN676. Electronic operation at two progressive / modulating stages
-
Continuous modulation operation by installing P.I.D. controller in the control panel (to be ordered separately with modulation probe)
-
Modulation ratio 1:10
-
Gas burner with low NOx and CO emissions in accordance with European standard EN676: class 3
-
Regulating combustion air and blast-pipe
-
Combustion air intake with throttle damper. Air flow adjustment with electric servomotor
-
Fully closing air damper on shutdown to avoid loss of heat through the chimney
-
Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
-
Fixed boiler coupling flange
-
Easy maintenance thanks to the two-sides hinge which allows the removal of the combustion head without having to remove the burner from the boiler
-
CE version main gas train is complete with operation and safety valve with electromagnetic drive, valve tightness control, minimum and maximum pressure switch, pressure regulator and gas filter
-
Fail proof connectors for burner/gas train connection
-
Gas train exit: up
-
Flame detection by ionisation electrode with connector for micro amp meter
-
Control panel with display diagram for working mode with indication lights
-
Terminal board for the electric and thermostatic connections to the burner
-
Terminal board for second stage operation or for the connection of the PID electronic regulator
-
Electrical system with protection rating IP54
-
Gas burner compliant with European standard EN676. Electronic operation at two progressive stages
-
Continuous modulation operation by installing P.I.D. controller in the control panel (to be ordered separately with modulation probe)
-
Modulation ratio 1:12
-
Gas burner with low NOx and CO emissions in accordance with European standard EN676: class 3
-
Combustion air intake with throttle damper. Air flow adjustment with electric servomotor
-
Fully closing air damper on shutdown to avoid loss of heat through the chimney
-
Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
-
Fixed boiler coupling flange
-
Easy maintenance thanks to the two-sides hinge which allows the removal of the combustion head without having to remove the burner from the boiler
-
Device made of sound-absorbing material to reduce fan noise
-
CE version main gas train is complete with operation and safety valve with electromagnetic drive, valve tightness control, minimum and maximum pressure switch, pressure regulator and gas filter
-
Fail proof connectors for burner/gas train connection
-
Gas train exit: up/down
-
Flame detection by ionisation electrode with connector for micro amp meter
-
Control panel equipped either with display showing the working process and with the keyboard for the burner adjustment
-
Terminal board for the electric and thermostatic connections to the burner
-
Terminal board for second stage operation or for the connection of the PID electronic regulator
-
Electrical system with protection rating IP54
Technical Descriptions (TBG1100 MC)
-
Gas burner compliant with European standard EN676. Electronic operation at two progressive / modulating stages
-
Continuous modulation operation by installing P.I.D. controller in the control panel (to be ordered separately with modulation probe).
-
Modulation ratio 1:11
-
Gas burner with low NOx and CO emissions in accordance with European standard EN676: class 2
-
Combustion air intake with throttle damper. Air flow adjustment with electric servomotor
-
Fully closing air damper on shutdown to avoid loss of heat through the chimney
-
Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
-
Fixed boiler coupling flange
-
Easy maintenance thanks to the two-sides hinge which allows the removal of the combustion head without having to remove the burner from the boiler
-
Device made of sound-absorbing material to reduce fan noise
-
CE version main gas train is complete with operation and safety valve with electromagnetic drive, valve tightness control, minimum and maximum pressure switch, pressure regulator and gas filter
-
Fail proof connectors for burner/gas train connection
-
Gas train exit: down
-
Flame detection by ionisation electrode with connector for micro amp meter
-
Control panel with display diagram for working mode with indication lights
-
Terminal board for the electric and thermostatic connections to the burner
-
Terminal board for second stage operation or for the connection of the PID electronic regulator
-
Electrical system with protection rating IP54
ติดต่อเรา
ท่านสามารถติดต่อสอบถามขอรายละเอียดการใช้งานสินค้าหัวพ่นไฟ หรือราคาได้ที่
Tel : 02-898-3000, 081-835-0842
หรือสามารถขอใบเสนอราคาได้ที่
Fax : 02-898-3336, 02-898-3323
E-mail : sales_bangkok@vanichgroup.com